Terminating
Permaseal connectors (using EXC7017) (Click Here to see our selection of Permaseal
connectors).1. Using a 2-Bladed stripping tool (EXC7010), strip coax as shown to right, exposing 3/8" of the
center conductor and remove 1/4" of the outer coax insulation. Then cut the
center back to having 1/4" exposed, this insures that the center is cut clean
and points out straight.
2. Fold the braid back over the outer
jacket as shown to right. |  |
| 3.
Insert the tool fitting required for the connector (see
below). |  |  |  | | BNC | F100 | RCA |  |  |  | | 4. Carefully
insert the coax into the connector as shown until firmly seated. In some cases,
it may be easier to insert the connector into the tool first and then slide the
wire through the end of the tool to the connector. Do not force into connector.
The dielectric can get caught on the inner barrier, kind of rotate or wiggle to
ensure the dielectric passes through the inner barrier. Continue pushing in to
allow the wire to seat firmly. |  |  |  | 5. Use the tool
(EXC7017) to compress the back of the connector. It may
be necessary to adjust the tool for a proper compression. The numbered parts
are as follows:- 1. Connector insert (shown above), turn to insert or
remove the connector insert.
- 2. Holder for insert, turning this piece makes
it move up or down for compression height
- 3. Used to lock the adjustment, if
#2 doesn't turn freely, this one is probably stopping it, turn this in order to
allow #2 to adjust.
|  | | Use pictures below
to determine if tool has sufficiently compressed the
connector. |  |  |  |
|